Listen to this one instead. This article is also an episode of the Field Notes from RCS podcast: about thirty minutes, in Mike's voice, with the subscriber's question that started it, why laying an anode down is the knee-jerk fix, and a couple of ideas for the design engineer. The episode page has the player, the show notes, and a full transcript.

Article 0080 — The Crowded Groundbed

FIELD NOTES FROM RCS

Article 0080 — The Crowded Groundbed

00:00
00:00

You've got the first stake in the ground, 350 ft off the pipeline. The drawing shows 14 anodes in a single line running straight away from the pipe, 20 ft apart, each one augered to 15 ft. That's 260 ft of groundbed. You pull the tape and the property line comes up at 208 ft.

The bed is 52 ft longer than the ground that was bought for it. Sliding it toward the pipe would fix that, but the owner is firm: the first anode goes no closer than 350 ft.

So the crew discusses the problem, and three ideas come out. Hold the 20 ft and leave the last three anodes off. Hold the 20 ft as far as it goes, then bunch the last few up against the property line. Or tighten every space to 16 ft and get all 14 in.

The first two come from the same thought, and it is a common belief in our industry, especially on big beds: keep the design spacing and let the last anode or two take the hit. “Better one suffers than all of them,” or “I’d rather have most of the bed installed to the design than move all of them.”

It sounds right. The math doesn't back it up.

Meanwhile the owner's rep is standing there with questions. How bad is it, and what are my options?

❝

The installer doesn't always make the call. But the installer is usually the first one asked.

Here's what to tell them.

Cleared ground during an impressed current groundbed installation, with a skid steer moving dirt and an excavator digging the anode holes.

Every Groundbed Is Already Crowded

Start with one anode in its coke column. It has a resistance to earth, set mostly by the soil resistivity and the length of the column. Put a second one a long way off, wire the two together, and the pair has half the resistance. Fourteen of them would have one-fourteenth. That's simple parallel math, and it's the best case. It only holds when the anodes are far apart.

In a real groundbed they never are. Current leaving an anode raises the voltage of the soil around it, measured against soil far away. It is highest at the anode and fades with distance, and it reaches the anodes on either side. Every anode in the line is pushing current into ground that its neighbors are already pushing on. The course manuals call it mutual interference, or crowding: the anodes are competing for the same path through the soil.

At 20 ft, about 13% of one anode's voltage shows up at the anode next to it. At 10 ft it's about 22%. Add up every neighbor's share along the line, and the 14 anodes in this design do the work of about 8.6 anodes spaced far apart.

Diagram of a line of groundbed anodes showing how each anode raises the voltage of the soil around it, with about 13% reaching a neighbor at 20 ft and about 22% at 10 ft.

Each anode raises the voltage of the soil around it. At 20 ft the anode next door sees about 13% of it. At 10 ft, about 22%.

That isn't a flaw in the drawing. The designer knew it and counted it. Crowding is in every groundbed ever drawn, so the question at the property line isn't whether squeezing the bed adds crowding. It's how much more.

The Equation

The designer's tool for this is Sunde's equation for a line of vertical anodes. It made a short appearance in Current Response Testing. Here it is again, because everyone loves a little math. This time, look at what each variable does to the answer.

R = (ρ / 2πNL) × [ ln(8L/d) − 1 + (2L/S) × ln(0.656N) ]

  • R is the resistance of the whole groundbed to earth.

  • ρ is the soil resistivity.

  • N is the number of anodes.

  • L and d are the length and diameter of the coke column, not the anode.

  • S is the spacing between anodes, center to center.

Keep ρ, L, d and S in the same length units, ohm-cm with centimeters. The textbook version swaps 1/2π for 0.00521 so the lengths can go in as feet.

Drop the last term and what's left is Dwight's equation for one anode, divided by the number of anodes. That's the simple parallel answer. The last term, (2L/S) × ln(0.656N), is the crowding. You don't have to run it to read it.

  • S is on the bottom. Tighter spacing, bigger penalty.

  • L is on top. The longer the coke column, the bigger the share of the bed's resistance that comes from crowding.

  • N is inside the logarithm. Every anode you add crowds all the others a little more.

  • ρ multiplies everything. The same squeeze costs more ohms in high-resistivity soil.

What Tighter Spacing Costs

Run this bed through the equation at one spacing after another and you get the curve below. It's an illustrative example: 14 anodes on 10-ft coke columns in 10-in holes, with the same soil top to bottom.

Chart of groundbed resistance against anode spacing for the 14-anode example bed. Resistance climbs as spacing tightens: about 4% over the design at 18 ft, 10% at 16 ft, 26% at 12 ft and 38% at 10 ft.

Groundbed resistance against spacing for the example bed. The shaded band is 10% over the design.

  • 18 ft: about 4% more groundbed resistance than the design.

  • 16 ft: about 10% more. The 14 anodes now work like 7.9.

  • 12 ft: about 26% more.

  • 10 ft: about 38% more. They work like 6.2.

  • 5 ft: more than double.

The curve is gentle near the design spacing and steep once the anodes close in. That shape is why designers settle where they do. Spacing is a trade between resistance on one side and cable, trenching and right-of-way on the other. Past the knee of the curve, more spacing buys less and less.

For a yardstick, Peabody's Control of Pipeline Corrosion says a groundbed design can be called a success when the finished bed consistently lands within 10% of the calculated resistance. The calculation itself is only that good. So a change that moves the bed 4% is lost in the noise. A change that moves it 38% is a different groundbed, and a rectifier sized for the design may not have the voltage to push its current through it.

Two cautions. This curve belongs to this bed. More anodes or longer columns make it steeper, and fewer or shorter ones flatten it, so don't carry these percentages to another job. And 10% more groundbed resistance is not 10% more rectifier voltage. The bed is one piece of the circuit, along with the cables, the pipe's own resistance to earth and the back voltage.

❝

A couple of feet is inside the tolerance of the calculation. Half the spacing is a different groundbed.

Spread It, Crowd the End, or Drop Three

Back to the property line. Sunde's equation assumes every space is the same, so by itself it can't compare the three ideas. The same math can be set up with every gap different: hold all the anodes at one voltage and solve for the current each one carries from where it sits. De Las Casas and Bianchetti work through groundbeds like that in Potential Theory Applied to Cathodic Protection Design. We ran this bed three ways. The numbers are illustrative, and at these spacings they come in about a point under Sunde's.

Diagram of three ways to fit a 260-ft groundbed design into 208 ft of ground: spread all 14 anodes at 16 ft, hold 20 ft and crowd the last four spaces at 7 ft, or hold 20 ft and drop three anodes. Resistance comes out about 9%, 11% and 22% over the design.

Three ways to fit a 260-ft design into 208 ft of ground.

  • Spread it. All 14 anodes at 16 ft. About 9% over the design resistance.

  • Crowd the end. Hold 20 ft for the first ten anodes, then fit the last four spaces at 7 ft. About 11% over.

  • Drop three. Hold 20 ft and install the 11 that fit. About 22% over.

Spreading wins, and dropping anodes loses by a wide margin. But resistance is only half of it. Look at what each anode carries.

In any line of anodes the ends carry more current than the middle, because an end anode has neighbors on one side only. In this design each end anode carries about 8.4% of the bed's current and the ones in the middle about 6.7%. Spread the bed to 16 ft and those shares barely move.

Crowd the end, and the squeezed anodes drop to between 5% and 7% while the anode at the far end climbs past 9%. Drop three, and the 11 that are left each carry about a quarter more current than the design gave them, for the life of the bed. Anodes are consumed by the current they discharge.

❝

Spread the shortage and no anode suffers much. Drop one and every anode left works harder.

To be fair to the belief, it holds up when the miss is small. Come up 10 ft short on this bed and shortening only the last space costs the same as trimming a little off every space, between 1% and 2% either way. It stops working as the shortage grows.

Would a Couple More Anodes Help?

It's the next question every time. The answer is yes, but less than most people expect, because each added anode crowds all the others. On this bed, two more anodes in the same 208 ft buy back about half of what the squeeze cost. Getting all the way back to the design resistance takes four to six more.

The other lever is rectifier voltage, if the unit was sized with the headroom. Past that, the designer has options the installer doesn't: a second row of anodes where the site is wide but not long, longer coke columns, or a different type of bed.

What not to do is slide the bed somewhere else without new soil resistivity measurements. The AUCSC Advanced Course tells of a groundbed that was moved 30 ft toward the foot of a hill for right-of-way reasons, and nobody took new ones. It came in at about ten times the resistance it would have had at the original spot. A few feet of spacing costs single digits. The wrong soil costs multiples.

When the Auger Won't Go

Say the owner approves 16 ft and the crew starts augering. Eleven holes go to 15 ft. Three don't. The auger stops on rock at about 8 ft, the crew moves over a few feet and tries again, and it stops again.

Most owners don't want an anode set in rock. After a couple of tries the request goes up the line: can these three go in horizontal?

Start with why the drawing said vertical. The AUCSC Intermediate Course gives the main reason: vertical anodes can usually be placed in permanently moist soil, which generally means lower resistance and fewer anodes. The depth on the plans isn't arbitrary either. The design is built on the soil resistivity and the water table at that depth. Vertical anodes also fit where surface area is limited.

Now what horizontal changes. The surprise is that the geometry costs very little. In the same soil top to bottom, one anode in an 8-ft coke bed laid at 6 ft comes out about 8% higher in resistance than the same anode in its 10-ft vertical column. Stretch that coke bed to 10 ft and the two are about even. Lay three of this bed's 14 anodes horizontal and the whole groundbed moves about 1%.

Sketch comparing a vertical anode in a 10-ft coke column from 5 ft to 15 ft deep with a horizontal anode in a coke bed at 6 ft. In the same soil the horizontal anode comes out about 8% higher in resistance.

The vertical column works the soil from 5 ft to 15 ft. The horizontal anode sits in the top 6 ft.

The risk is the soil. Every number in this article assumes the soil is the same from top to bottom, and it never is. The vertical column works the ground from 5 ft down to 15 ft. The horizontal anode sits in the top 6 ft, the part that dries out in a dry season. If the resistivity at the site gets better with depth, the horizontal anodes are in the worse layer and the equations make them look better than they are. If the best soil is on top, laying them down may cost nothing.

So the question to send the designer is what the four-pin readings did with depth. A reading at a given pin spacing averages the soil from the surface down to about that depth, so readings at 5, 10 and 15 ft tell the story. If nobody has them for this spot, they take a few minutes.

Close-up of an excavator digging the hole for a horizontal impressed current anode.
  • Depth. Deeper is better, mostly for the moisture. By the equation alone, going from 4 ft to 8 ft lowers one anode's resistance by less than 10%. A common minimum is about 3 ft of cover over the top of the anode and its coke.

  • Coke. A horizontal hole is bigger than an augered one, so it takes a little more. On our jobs a typical horizontal anode gets 12 bags: five in the bottom, set the anode, seven over the top. If you're adding coke, add it as length along the anode. Length is out front in the equation. Diameter is inside the logarithm.

  • Coverage. Vertical or horizontal, the anode ends up in the middle of the coke, fully covered, with no voids.

  • Continuous coke. A design can also call for one unbroken strip of coke with the anodes spaced inside it, which makes the row act like one long anode. It's a recognized method. It just doesn't show up on many drawings.

Who Decides

On most jobs, none of this is the installer's call. The installer's job is to see the problem first and contact the right people with some options.

Most groundbed drawings carry a note that any change has to be approved by the design engineer. AMPP SP0169-2024 says the same from the other direction: the work follows the construction drawings and specifications, exceptions need the appropriate approvals, and every deviation goes on the as-built drawings.

On the job behind this story, the design engineer ran the numbers, the owner agreed to 16 ft, and the full bed went in on the ground that was there. Whatever changes, write it down: the spacing, which anodes were laid horizontal, and how deep. The next person to troubleshoot that groundbed will be working from the drawing.

Then check it. When the rectifier is energized, the resistance check tells you where the circuit landed against the design number. The First Tap is Misleading covers how to take that reading without fooling yourself.

This issue started with a reader's question. If there's a field problem you'd like to see worked through here, reply to this email or leave a comment.

Key Takeaways

  • Crowding is in every groundbed. Anodes in a line share the soil. In this example, 14 anodes at 20 ft work like about 8.6.

  • Sunde's equation shows what crowding depends on. Tighter spacing, longer coke columns and more anodes all raise it. Soil resistivity multiplies the result.

  • Small squeezes are small. On this bed 18 ft cost about 4% and 16 ft about 10%, around the tolerance of the calculation. At 10 ft it was 38%.

  • Spread the shortage. Even spacing beat crowding the end. Dropping anodes cost more than twice as much and made every anode left work harder.

  • A couple more anodes help less than you'd expect. Each one crowds the rest.

  • Horizontal isn't the problem. The soil it sits in might be. Ask what the resistivity did with depth, add coke as length, and cover the anode completely.

  • Changes go through the design engineer and onto the as-built. Don't relocate a groundbed without new soil readings.

Tip Jar
Field Notes is free. If this one helped, you can leave a one-time tip. No subscription.
Other amount

Referenced Standards & Technical Resources

  • AMPP SP0169-2024 — Control of External Corrosion on Underground or Submerged Metallic Piping Systems (Section 8, installation of CP systems)

  • Peabody's Control of Pipeline Corrosion, 3rd Edition — Chapter 7, "Ground Bed Design," and Chapter 5 (soil resistivity)

  • R. De Las Casas and R. Bianchetti, Potential Theory Applied to Cathodic Protection Design (AMPP, 2024) — groundbeds with unequal spacing and the current carried by each anode

  • T. H. Lewis, Jr., Deep Anode Systems: Design, Installation, and Operation — spacing of parallel systems

  • P. R. Roberge, Corrosion Basics: An Introduction, 3rd Edition — Chapter 11, anode beds

  • AMPP/NACE CP 1 — Cathodic Protection Tester and CP 3 — Cathodic Protection Technologist (course manuals)

  • AUCSC Intermediate Course (2025) and AUCSC Advanced Course (2022) — impressed current installation and design chapters

Roberts Corrosion Services, LLC

Established in 2011, Roberts Corrosion Services, LLC delivers comprehensive, turn-key cathodic protection and corrosion control solutions nationwide. Our end-to-end expertise encompasses design and inspection, installation and repair, surveys and remedial work. We provide drilling services for deep anode installations and a full laboratory for analysis of samples and corrosion coupons, as well as custom CP Rectifier manufacturing.

While our initial focus was on the Appalachian Basin area, we complete field work all over the US. We are a licensed contractor in many states and can complete a wide range of services.

Our biggest strength is in our flexibility for our clients. Solutions and Results.

Let us know how we can help.

Location: 39.251882, -81.047440

(304) 869-4007