This website uses cookies
Read our Privacy policy and Terms of use for more information.
Community
Members
Deep Dives
Advanced Topics
Study / Training
Materials
Sep 10, 2026
Article 0077 — A test station shunt has a ceiling and a floor. The amp rating is the ceiling. Your meter's last digit is the floor. Pick the shunt for the current you expect, or a healthy anode bank will read 0.0 mV.
Aug 19, 2026
Article 0076 — The number I gave our crews for years was right. The reason I gave for it was wrong, and the difference matters more than I expected.
Aug 4, 2026
Article 0074 — It is a condition, not a number of feet. You find it with a voltmeter, it moves with the current crossing the pipe, and the place it hides is the one place you most need it.
Jul 26, 2026
Article 0073 The series is a measurement, not a ranking handed down from chemistry. The version most of us memorized was built in seawater, the soil version reads differently, and on the soil version steel appears four separate times.
Jul 20, 2026
Article 0072 A calibration sticker proves the instrument, not the reading. How to field-verify your DFT, profile, durometer, and holiday gages before you trust the numbers.
Jul 6, 2026
Article 0071 A foreign CP system can shift your readings without exchanging any current with your pipe. Interference damages steel; influence damages data. Test before you bond.
Jun 27, 2026
Article 0070 Field Kits vs. Lab Analysis in the Race Against Chemistry Change
Jun 18, 2026
Article 0069 A disbonded coating can wall off the very steel it was meant to protect.
Jun 10, 2026
Article 0068 Where OIL RIG came from, why the names mislead, and the trap that catches good techs.
Jun 3, 2026
Article 0067 Your potential tells a story. An external corrosion coupon tells the truth.
Jun 1, 2026
Article 0066 Protecting the Coating After Inspection is Done
May 29, 2026
Article 0065 When the voltmeter reads protection but the steel is still corroding — and how the composite reading hides what's actually happening at the pipe.
May 22, 2026
Article 0064 How each method works, where each tends to do well, where each tends to struggle, and what to weigh when you're deciding between them.
May 15, 2026
Article 0063 On the generation of corrosion technicians that's retiring, the one coming up behind it, and what gets lost in the handoff.
May 10, 2026
Article 0062 When CP is Pushed Past its Upper Limit
May 4, 2026
Article 0061 Why the Small Details Often Decide Coating Performance
May 3, 2026
Article 0060 Why the Ohmmeter Lies - and What to Use Instead
Apr 28, 2026
Article 0059 A systematic approach to diagnosing rectifier problems from the incoming AC to the output terminals
Apr 26, 2026
Article 0058 Design calculations get you close. Field testing gets you there.
Apr 21, 2026
Article 0057 A field-first guide to capturing, labeling, organizing, and preserving inspection photos that still make sense later.