Transcript 0:00 [upbeat music] This is Mike Roberts with Roberts Corrosion Services, and this is the episode to discuss Article 78, the first tap is misleading. Quick story on the title. The first title was The First Tap Lies. 0:18 I thought that sounded a little bit rough, so I softened it some. The First Tap Lies still shows up later in the article as a section heading, which is kind of funny that I didn't update that. [laughs] Anyway, 0:31 the idea to put this article together actually came from some field work we were doing recently. We had just installed a ground bed and a rectifier on a project. 0:41 The installation went great, and the client was happy with it. It was a surface bed, over a dozen anodes set remote from the pipeline. We were also doing a DCVG survey on that same line. 0:54 The rectifier was hung, but it didn't have power yet, so we were running it off a generator, and we figured we'd use that to get a shift on the pipe for the DCVG. There's a whole issue on DCVG in the archive. 1:07 The short version, you need a certain amount of shift on the pipe for the survey to work, and on a new pipeline, it doesn't take much current to get there, so the rectifier gets set very low. We were essentially native. 1:20 So we set it on the first tap, kicked it on, had plenty of shift, and got ready to go, and Levi looks at the meter and says, "Hey, that's pretty high resistance for a bed we just put in." 1:33 Any other time, that might not have meant as much to me. This one stings because we installed that ground bed. It was supposed to be a lower resistance bed. We selected the location. We did the soil resistivity. 1:47 It should work great there. So why is it so high? It all comes back to what's called back voltage or what the article calls back EMF. 1:58 On that first tap, we were seeing more of that, and it was making the ground bed appear to have a high resistance. 2:04 Most of that goes away once you turn the output up and the back voltage becomes a small piece of what the unit's putting out. That's what sparked the article. 2:13 A lot of times, when people commission a rectifier, they just turn it on and kinda pick a setting. Sometimes it's comical. We'll set it about fifty percent, halfway up, 2:25 or we'll go with B1 because all my other ones are on B1. As much as that seems silly to say out loud, [laughs] it's amazing how many people actually do it that way. 2:37 So I thought we'd talk about that back voltage, what a high resistance ground bed looks like, and how you actually dial in a rectifier and figure out what the tap setting should be. 2:47 If everybody keeps turning the music up, the whole apartment building has loud music. I believe that same analogy appears in the article as well, so we'll get there. 2:57 We have a wide audience with the newsletter, corrosion engineers, technicians, and folks that are new to the industry. 3:04 So we generally start with a situation, what's going on that led to the topic, and it's usually a field situation. In this case, it's a new rectifier, very much like how it actually happened. 3:16 Of course, we changed the numbers to protect the innocent. The rectifier is hung, the cables are terminated, and the ground bed has had time to settle. 3:26 You put the coarse tap on A and the fine tap on one, flip the breaker, and read the output. Three volts, half an amp. That's six ohms. The design planned for one to two. 3:39 Depending on where you're at in the country, six ohms might be great or it might be awful. Where we were, not so great, especially with a design that planned for much less. 3:49 It's tempting to write it down as a high resistance bed and start making phone calls. Hold off. 3:55 The lowest tap is the worst place to quickly judge a ground bed, and the reason is a voltage that was sitting in the circuit before you ever turned the unit on. 4:04 The first tap is the worst place to quickly judge a ground bed. The first thing people think, and it's usually what I'd think too, is an installation problem. The rectifier's messed up. There's a cable break. 4:16 Not all the anodes got tied in. Maybe not enough Coke breeze. Generally, it points at the installation. I could have done the same thing, except we did the installation, so I knew it was solid. 4:28 Kicking on a new rectifier is a commissioning job, not a switch you flip. 4:32 Review the system, pick the places to watch, take a baseline, and step the taps up while monitoring until the worst location is protected and the most negative one isn't overdone. 4:43 That's really the whole point of the article. Let's go through it step by step. Before anything gets power, walk the installation against the plan. Positive cable to the anodes, negative to the structure. 4:57 Check the test stations at the ends of the bed and any bonds or junction boxes the design calls for. A lot of operators ask for a loop cable. 5:07 The positive runs past the last anode and loops back toward the rectifier left unconnected. If the positive breaks, every anode past the break is cut off. 5:18 With a loop, you connect the far end and run the bed from the other side while the repair gets planned. If the system has one, make sure the loop end is set up the way the owner wants it. 5:29 On a deep anode well, give the carbon backfill at least twenty-four hours after the final pumping to settle before you energize. At the rectifier, the safety habits from the rectifier troubleshooting issue apply. 5:42 That's one thing I liked about this article. With so many articles on the site now, we don't have to explain every topic in detail. We point at the issue that already did. 5:52 There's three, four, five places in this article that link back to earlier ones, and I'll do the same here. There's a whole issue on rectifier troubleshooting in the archive. The short version, follow your SOP. 6:06 Check the case for AC voltage to ground before you touch it, and again after you energize. Leads on with the unit off, hands out of the cabinet, then turn it on to read. 6:17 Then three readings before you add any current to the line. One, the back EMF, short for back electromotive force. Some books call it back voltage. 6:28 With the unit off and the cables connected, measure the DC voltage between the structure and anode terminals. 6:35 That's the galvanic voltage between the steel and the anodes, or the carbon backfill, usually one to two volts. Write it down. You'll need it in a few minutes. Two, the AC supply. 6:48 It has to match how the rectifier is wired. Most units can be set up for one twenty or two forty, so check that the configuration matches the supply you've got before you energize. 6:58 Three, the tap voltages from the manufacturer's chart or measured between the taps with one DC cable off so nothing goes out on the line. 7:07 The way I'd put it, walk through the whole system, make sure everything's tight and the cables are correct, then kick it on at the lowest setting. 7:15 With any electrical equipment, it's good to energize on the lowest tap in case something's wrong. And here's the thing to know, that lowest setting is also what will show the highest resistance in your bed. 7:27 You've got the voltage and the current, so do a quick math check with Ohm's Law. It's not perfect because everything else in the circuit is in that number, so it's kind of a total circuit resistance, but it's a start. 7:40 Now, before you start stepping it up, you want some locations picked out on the structure you're trying to protect. 7:47 In our case, it was a pipeline, so we'd already picked spots near the rectifier, ahead of us, and behind us. If we'd been commissioning, this is how we've done it. 7:56 The rectifier location, some foreign line crossings, some road crossings, a few items like that. 8:03 You get some baseline data, record what you need to record, and then see what kind of difference this new system makes on top of what you already have. The article's list. 8:14 You can't read the whole line after every tap change, so pick the places that tell you what the line is doing and make them easy to get to. 8:22 On a ten-mile line, that might be every road crossing or five or six test stations end to end. A few go on every list. Next to the rectifier, read it before you energize and right after. 8:37 The pipe should go more negative, and if it moves the other way, shut the unit down and check the cables. The far ends of the section, the hardest places to impact. Foreign line crossings. 8:49 Trouble spots, because if the unit was added to help a weak area, that's why you're there. Insulating joints and cased crossings. 8:58 Mark each spot with a stake or paint so the reference electrode goes back in the same place and split the list among the crew. One tech reading every location after every tap change makes for a long day. 9:11 This step always goes a little differently depending on the system. In our case, this was the only rectifier on that line, so it was the only contender we had to work with. 9:22 A lot of times you're adding a unit to a long pipeline that already has several rectifiers, or you're in a congested area where other people are bonded to you or affect you. 9:32 You have to deal with that first before you can call anything your baseline. What you're after is this. What are my interrupted potentials before I turn on this new unit? 9:44 That's your baseline, and we don't want to get that confused with native. If the system is completely by itself, the only system, nothing's been kicked on yet, that could be a native. In most cases, it's just a baseline. 9:58 So if other CP sources exist, interrupt everything you can that influences your locations, other rectifiers, bonds, galvanic anodes, and foreign rectifiers where the owner agrees. GPS synchronized interrupters. 10:13 Three seconds on and one second off is common. Then, with the other sources cycling and the new unit off, read on and instant off at every location. 10:24 If the unit was installed to help a trouble area, that area's baseline is the number to beat. One caution. A baseline taken with other systems running can't be used to meet the hundred millivolt polarization criterion. 10:38 That criterion counts from a true native or a decay with every influencing source off. This article works toward negative eight fifty millivolts to a copper sulfate reference cell, instant off. 10:51 Now the part the title's about. Start at the lowest tap. It's a safety habit, and it's how the procedure is written in the books. 11:00 Read volts and amps with your own meter at the output terminals and across the panel shunt. Panel meters can and do fail. The rectifier doesn't push much current until its output climbs past the back EMF. 11:15 You'll usually see something, but it's very low. A couple of volts and next to no amps on the first tap may be all that is, so step up. 11:24 If a higher tap still shows only the back EMF and next to no amps, suspect the rectifier or its AC supply before you go looking for a cable break. 11:34 Once current flows, volts divided by amps gives you the effective circuit resistance. On the first tap, though, it reads high because the back EMF is a big share of a small voltage. 11:45 Holtzbaum, in Cathodic Protection Survey Procedures, puts it flat. It is incorrect to simply divide the output voltage by the output current without accounting for the back EMF. So take the back EMF out first. 11:59 Resistance is volts minus back EMF divided by amps. Take that first tap, three volts, half an amp. Divide and you get six ohms. But two of those three volts are back EMF. 12:12 The bed only sees one volt, and one volt at half an amp is two ohms. So while it's most likely a two-ohm bed, when you're on A1, it reads as a six-ohm bed. That's what it comes out to. 12:26 When you do that short little equation and subtract the back voltage out, it knocks it right back down to two ohms, which is what it actually is. And you can do that at each tap setting. 12:36 And if you do, the corrected number comes out two ohms every time. The plain number just slides from six toward two as the taps go up because the back EMF becomes a smaller piece of a bigger voltage. 12:49 The table in the article has all four taps if you want to see it on paper. The bed didn't get better as the taps went up. That's how a good bed ends up labeled high resistance off a reading or two at the lower outputs. 13:01 The bed didn't get better when you turned it up. The back EMF just got smaller next to the voltage. In my experience, once you get past about B1 or so, the back voltage really doesn't come into play very much. 13:13 If you're already that high, you can just use simple Ohm's law to see about what the bed resistance is. The article's own table backs that up. 13:21 Plain volts over amps is three times too high at A1 and only about 20% high by B2. In the lower settings, like where we were, you need to know this stuff. 13:34 If you expected two and you're looking at 50, stop and troubleshoot before you balance anything. It could be a cable, a connection, or the bed itself. 13:44 There's a whole issue on locating and repairing cable breaks in the archive. Now, how to figure out which setting you want. 13:52 I did try to simplify this in the article because in a lot of cases, it gets very complex with a lot of things and sometimes several systems. 14:01 To get the concept across, we looked at this one system, this one pipeline, the readings at the spots we'd picked, and what kind of output gets what kind of potential. The default is one step at a time. 14:15 Raise the fine tap one position, energize, and read. When the fine tap tops out, put it back on one and move the coarse tap up one. A six goes to B1, not B6. 14:29 If a step barely moves anything, going up two or three is reasonable. The unit is off for every tap change. Give each step time to settle. 14:40 At every step, read the output volts and amps, then on and instant off at every location, and watch how much each location moves per amp. By the second or third step, you can see where it's headed. 14:53 And we always want to look at interrupted potentials, whatever that polarized potential is. The on potentials aren't very helpful here. 15:02 Here's the same illustrative line with the two locations that drive the decision, the far end at mile 10 and the spot next to the bed near mile two. 15:11 All of these are instant off against copper sulfate, and they're all negative, so I'll quit saying negative every time. Baseline, new unit off. The far end reads about 690, and next to the bed, 720. 15:25 At A5, three and a half amps, 813 and 965. The far end is moving about 35 millivolts per amp. To get it past 850 with some margin, it needs about 50 more, which is another amp and a half, five amps total. 15:42 The spot next to the bed moves about 70 millivolts per amp, so five amps puts it near 1.07 volts. And that's B2. Five amps, 865 at the far end, 1.07 volts next to the bed. 15:57 The article's second figure is that picture, the far end climbing toward the 850 line and the spot next to the bed climbing faster toward the ceiling. 16:06 Early instant off readings understate where the line will settle because polarization keeps building after each step. That's one more reason to step up to your final setting instead of overshooting and backing down. 16:18 What you read right after a step is going to drift more negative on its own. So the whole premise is this. You're going to have a place that's the worst spot on your structure. You want to monitor that. 16:32 You're going to have a place next to your rectifier that's probably going to be the highest. You want to monitor that too. And then road crossings, line crossings, and a bunch of stuff in between. 16:44 The idea is to get the worst looking area you're trying to help up above the 850 criteria without causing the other areas to get way too high. 16:53 That's a balancing act, and that's why they call it balancing and commissioning. The article's numbers. 17:00 Get the worst location more negative than 850 millivolts, copper sulfate, instant off, without the most negative location going past 1.2 volts instant off, or your company's limit if it's tighter. 17:14 Peabody's describes the same two limits. The far point has to reach the minimum potential for protection, and the pipe near the bed stays less negative than about 1.1 volts to avoid coating damage and other issues. 17:29 The overprotection issue in the archive used 1.2, the AUCSC number. SP0169 2024 doesn't set an overprotection limit for steel, so if your company has a number, use it. The far end sets the floor. 17:46 The pipe next to the bed sets the ceiling. And if one location won't come up without overdoing the rest, find out why before you turn anything up. 17:56 Turning up won't protect a section cut off by a broken bond, and it can increase interference there. 18:02 Low spots also come from poor coating, poor continuity, a shorted insulating joint, contact with a foreign structure, or a shorted casing. It does take a little bit of time to set in. 18:15 Once you've got it set, check it again a few days later and see where it's at. Sometimes a little more balancing needs to come into play. A well-coated new line can polarize quickly. 18:28 Bare or poorly coated pipe can take days or weeks. So the setting you leave with is your best read, not the final number. Go back in a few days to a week and read the locations again. 18:41 In the example, a week later, the far end had settled at 880 and the spot next to the bed at 1.095 volts. Still inside the window. 18:52 And then anytime you're commissioning or balancing a new system, make sure your neighbors know about it. That's the apartment building. Everybody's got a stereo. If you can't hear your own music, you turn it up. 19:04 Then your neighbor turns theirs up. Pretty soon the whole building is blaring and nobody wins. Peabody's says the same thing in engineering terms. 19:14 Cooperating with the owners of other pipelines and buried structures is an essential part of the pipeline corrosion engineer's job so everyone can run their systems with the least practical effect on structures belonging to others. 19:27 And notify the owners of the structures that cross your line before the installation goes in so the conversation starts early. It's always good to have some communication with the other CP systems around you. 19:39 Even if they're not affecting you, let them know because your new system might affect them. It's a two-way street. 19:46 They might want to come out while you're balancing and commissioning and monitor their pipeline, check whether they actually pick up any current at your different tap settings or if it's just a voltage gradient. 19:56 During commissioning, read the foreign lines at your crossings and near the bed. 20:00 A foreign line that swings more negative near your bed may be picking up current or your bed's voltage gradient may just be reaching their reference cell. 20:08 There's a whole issue on DC interference versus DC influence in the archive. Finally, record all of it. Write it all down because that information is super valuable. 20:20 With some balancing and commissioning projects, you've got two, three, four people on it and you don't get that opportunity very often as a corrosion tech. 20:29 If you collect a lot of really good data at different rectifier outputs, it can really help you down the road when somebody's trying to decide whether something should be turned up or turned down and how the whole pipeline responds as you keep maintaining and monitoring it. 20:44 What goes in the record? 20:45 Nameplate data, as found and as left taps, output volts and amps at each step, the back EMF and both resistance numbers with the tap each came from, on and instant off at every location at every step, the interrupter cycle and the foreign line readings. 21:03 The commissioning numbers are the baseline every rectifier inspection after this one gets compared to. One note, this article covers tap type units. 21:13 Auto potential and constant current rectifiers are a whole different animal. They're set mainly on a control board, although they might have tap bars. Same goal, different procedure. 21:24 Follow the manufacturer's manual for those. Overall, I thought it was a pretty good article. 21:31 It dealt with something that just came up at work and for me, it was educational in that not everybody recognizes you don't just kick the thing on and crank it up. 21:41 So if you remember one thing from this one, kick it on at the lowest setting and don't judge the bed there. If it looks high on the first tap, take the back voltage out before you make a call. 21:54 Don't call your installation contractor and yell at them because the ground bed seems crappy. You got to know what you're looking at. 22:02 Then step it up one tap at a time, set it where your worst spot is protected and your best spot isn't overdone and write all of it down. 22:11 The full write-up with the figures and the standards behind it is on the newsletter site. Field Notes from RCS, Article 78, The First Tap is Misleading. And I want to make sure everybody's aware. 22:25 If you're a subscriber and you go to this article online, logged in, you can comment directly on the article and we see every one of those comments. A question, something to add, or just, hey, great article. 22:38 Folks are more than welcome. Those stick to the article and other people see them. You do have to be a subscriber and logged in to do that. 22:48 Until next time, this is Mike Roberts with Roberts Corrosion Services and we'll see you on the next one.